Maximize Performance, Versatility & Virtually Eliminate Downtime
Note: The ASX Series products have been discontinued due to parts obsolescence. For new applications or requirements, see the new LSX Series which offer more features and additional remote control interfaces.
The ASX Series is a family of fully featured, single and three phase AC Power Sources. Available models range from 1.5kVA to 6kVA with either Manual or Programmable Control. Cost effective and fully programmable for both basic frequency conversion and advanced AC power line disturbance test applications.
The ASX Series is a family of High Performance Switching AC Power Sources covering the power range from 1.5kVA to 6kVA. The product line offers both single and three phase models. Units are conservatively designed and output power ratings are based on the most severe combination of input line, output voltage, power factor, and temperature.
Great emphasis has been placed on low acoustic noise, ease of installation, and maximum power per cubic inch of rack space. Control and operational features provide a high degree of application versatility and ease of use for the test engineer. Applications range from simple, manually controlled frequency conversion to harmonic testing and sophisticated bus programmable transient simulation.
Power conversion within the ASX Series is achieved by high frequency pulse width modulation, resulting in cool, quiet and efficient operation.
Key Features Provide Application Versatility
- 22 Waveform Library – Arbitrary Waveform Generator
- 15 to 1,200 Hz Operation – 5,000 Hz Bandwidth
- Precision True-RMS metering of volts, amps, and power for displays and reporting
- Now compatible with UPC Studio graphical user interface
- RS-232 Interface with SCPI compatibility
- 1 Phase/3 Phase Switch Selectable Output from front panel or bus command
- 99 stored programs for both static and dynamic Transient Testing
- LabVIEW for Windows®/LabWindows® drivers
- Waveform Creation by Harmonic Synthesis
- Harmonic Analysis (Voltage and Current)
- Metering of RMS and Peak Values
- Continuous Self Calibration (CSC)
- Precision Voltage Programming – 0.05% with CSC engaged
- Programmable Output Impedance
- Up to 0-300 VAC Direct Coupled Out
- Power Levels from 1.5 kVA to 6 kVA
- Externally Referenced Meter Calibration
- CE and ETL Mark available
- Design Provides Total Control of AC Power
Design Provides Total Control of AC Power
- All ASX Series power source models may be equipped with a digitally programmable Oscillator/Controller or a manual version.
- Models 315ASX-UPC3C and 320ASX-UPC3C include HAS, Prog-Z and Inrush Current Measurement features.
- Single phase power source models may be controlled to operate on either a 0-135 VAC range or a 0-270 VAC range. Three phase models are additionally switchable 3ø to 1ø output power form.
- Total control of the output power form and the selection of either the direct output or the optional transformer output is available from the front panel or the bus.
- All operating functions may be controlled from either the front panel or from a remote RS-232 or IEEE 488.2/ SCPI BUS. LabVIEW for Windows® and LabWindows® Instrument Drivers are available.
Special ASX Series Operating Features
Continuous Self Calibration
Provides for exceptional accuracy of the AC output Voltage. When enabled, accuracy improves to ±0.1% referenced to the power source internal voltmeter.
Programmable Dynamic Output Impedance – Prog-Z (optional on UPC1/3)
Programmable Output Impedance provides the operator with the ability to dynamically control the output impedance of the AC Power Source. Using the output current term as conditioned feedback signal to the output voltage circuits, positive or negative impedance may be programmed. This control simulates the effects of, or compensates for high peak current, distribution, or transformer losses of up to ±10% of the output voltage.
This feature creates positive, negative, or zero output impedance (Zo).
- Compensates for line distribution or transformer losses.
- Simulates a soft power line for product testing. Compensation range is ±10% of the output voltage.
Waveform Library
Up to 22 different waveforms can be stored in the waveform library for execution as part of a steady state program or for substitution in any output phase as part of a transient test program. Memory location #1 is a non-editable high resolution sine wave. Locations 2-22 are editable and can be substituted in any output phase. An unlimited number of waveforms may be stored on the computer for those using a programmable UPC.
Waveform Edit
A full-featured editor permits modification of a stored waveform in both time and frequency domains. This method can be used to quickly create spikes, dropouts, notches and other sub-cycle wave conditions. The resulting modified waveform is stored for execution in steady-state or transient programs.
Waveform Analysis (optional on UPC1/3)
Provides both graphic and numeric displays of the harmonic structure of a voltage or current waveform. Each waveform is analyzed for its harmonic content up to the 51st harmonic. Amplitude and phase are reported to the local display
Waveform Synthesis (optional on UPC1/3)
Quickly create virtually any AC test waveform by building it out of harmonics. The process is as simple as keying in the magnitude and phase angle of each desired harmonic up through the 51st. Additionally, waveforms can be created by downloading from a host PC.
Time Based Transients
Create and execute transients that occur over a specified time segment to modify the output waveform, voltage, and frequency for any or all phases. An output trigger is provided for synchronizing external test equipment to the actual transient event.
Cycle Based Transients
Create and execute transients that substitute a waveform in any or all phases for 1 to 100 cycles. The waveform being substituted can be selected and/or modified from the waveform library.
AC Test Power
The ASX Series Power Source is equipped with a powerful microcontroller to create a fully integrated test system. It supplies a variety of power conditions to the device under test and meters/analyzes all output performance parameters.Frequency/Voltage Conversion
The ASX Series is an excellent source of stable AC voltage over the frequency range of 15 to 1200 Hz. The output frequency is quartz-crystal stabilized. Output voltages up to 600 VAC are provided.Phase Conversion
With the ability to provide singe and three-phase outputs, the ASX Series is the perfect choice to provide 1 Phase to 3 Phase or 3 Phase to 1 Phase conversion.Controller Selection Guide
Six controller models are available with the ASX-Series. They include 1 Phase and 3 Phase models for both manual and programmable control.- UPC-1M, 1 Phase Manual Control, 15 Hz to 1,200 Hz.
- UPC-3M, 3 Phase Manual Control, 15 Hz to 1,200 Hz.
- UPC-3EM, Export Version: 3 Phase Manual Control, 15 Hz to 1,200 Hz, reduced resolution.
- UPC-1, 1 Phase Programmable Control, 15 Hz to 1,200 Hz.
- UPC-3, 3 Phase Programmable Control, 15 Hz to 1,200 Hz.
- UPC-3E, Export Version: 3 Phase Programmable Control, 15 Hz to 1,200 Hz, reduced resolution.
Protective Transit Cases for Mobile Applications
Pacific Power Source offers rugged transit cases to protect your AC Source from adverse environmental conditions for mobile and/or military applications. Specific benefits:- Environmental Protection (shock, vibration, moisture, heat),
- Unrestricted Equipment Operation,
- Quick Cover Removal & Installation,
- Integrated wheels and Handles,
- Stainless Steel Latches.
- Available for following ASX models:
- 3U: 115ASX, 120ASX, 315ASX, 320ASX
- 5U: 140ASX, 160ASX, 345ASX, 360ASX
Model Comparison - Single Phase Models
Model | Rated Power (VA) | Voltage Max (L-N/L-L) (Vrms) | Rated Current Max (Arms) | Output Frequency (Hz) | AC Input | U |
---|---|---|---|---|---|---|
115ASX | 1500 | Direct: 132 | Direct: 16 | 15-1200 | 1Ø | 3 |
115ASXT | 1500 | Direct: 132 Transformer: 0-198 (T 1.5:1), 0-264 (T 2.0:1), 0-330 (T 2.5:1) | Direct: 16 Transformer: 10.7 (T 1.5:1), 8.0 (T 2.0:1), 6.4 (T 2.5:1) | 15-1200 | 1Ø | 3 |
120ASX | 2000 | Direct: 150/300 | Direct: 20/14 | 15-1200 | 1Ø | 3 |
140ASX | 4000 | Direct: 135/270 | Direct: 32/16 | 15-1200 | 3Ø | 5 |
140ASXT | 4000 | Direct: 135/720 Transformer: 202/404 (T 1.5:1), 270/540 (T 2.0:1), 338/600 (T 2.5:1) | Direct: 32/16 Transformer: 21.3/10.7 (T 1.5:1), 16.0/8.0 (T 2.0:1), 12.8/6.4 (T 2.5:1) | 15-1200 | 3Ø | 8 |
160ASX | 6000 | Direct: 132/264 | Direct: 48/16 | 15-1200 | 3Ø | 5 |
160ASXT | 6000 | Direct: 132/264 Transformer: 198/396 (T 1.5:1), 264/528 (T 2.0:1), 330/600 (T 2.5:1) | Direct: 48/16 Transformer: 32/10.6 (T 1.5:1), 24/8 (T 2.0:1), 19.2/6.4 (T 2.5:1) | 15-1200 | 3Ø | 8 |
Model Comparison - Three Phase Models
Model | Rated Power (VA) | Voltage Max (L-N/L-L) (Vrms) | Rated Current Max (Arms) | Output Frequency (Hz) | AC Input | U |
---|---|---|---|---|---|---|
315ASX | 1500 | Direct: 1Ø: 132/264 3Ø: 132 Transformer: 198 (T 1.5:1, only 3Ø), 264 (T 2.0:1, only 3Ø), 338 (T 2.5:1, only 3Ø)" | Direct: 1Ø: 12/8 3Ø: 4/Ø Transformer: 2.6/Ø (T 1.5:1, only 3Ø) 2.0/Ø (T 2.0:1, only 3Ø) 1.6/Ø (T 2.5:1, only 3Ø)" | 15-1200 | 1Ø | 3 |
320ASX | 2000 | Direct: 1Ø: 150/300 3Ø: 150 Transformer: 225 (T 1.5:1, only 3Ø), 300 (T 2.0:1, only 3Ø), 375 (T 2.5:1, only 3Ø)" | Direct: 1Ø: 20/12 3Ø: 7/Ø Transformer: 4.66/Ø (T 1.5:1, only 3Ø) 3.5/Ø (T 2.0:1, only 3Ø) 2.8/Ø (T 2.5:1, only 3Ø)" | 15-1200 | 1Ø | 3 |
345ASX | 4500 | Direct: 1Ø: 135/270 3Ø: 135" | Direct: 1Ø: 36/12 3Ø: 12/Ø" | 15-1200 | 3Ø | 5 |
345ASXT | 4500 | Direct: 1Ø: 135/270 3Ø: 135 Transformer: T 1.5:1 (1Ø): 202/404 T 1.5:1 (3Ø): 202/350 T 2.0:1 (1Ø): 270/540 T 2.0:1 (3Ø): 270/468 T 2.5:1 (1Ø): 338/600 T 2.5:1 (3Ø): 338/585" | Direct: 1Ø: 36/12 3Ø: 12/Ø Transformer: T 1.5:1 (1Ø): 24/8 T 1.5:1 (3Ø): 8/Ø T 2.0:1 (1Ø): 18/6 T 2.0:1 (3Ø): 6/Ø T 2.5:1 (1Ø): 14.4/4.8 T 2.5:1 (3Ø): 4.8/Ø" | 15-1200 | 3Ø | 8 |
360ASX | 6000 | Direct: 1Ø: 132/264 3Ø: 132 | Direct: 1Ø: 48/16 3Ø: 16/Ø" | 15-1200 | 3Ø | 5 |
360ASXT | 6000 | Direct: 1Ø: 132/264 3Ø: 132 Transformer: T 1.5:1 (1Ø): 198/396 T 1.5:1 (3Ø): 198/343 T 2.0:1 (1Ø): 264/528 T 2.0:1 (3Ø): 264/457 T 2.5:1 (1Ø): 330/600 T 2.5:1 (3Ø): 330/572" | Direct: 1Ø: 48/16 3Ø: 16/Ø Transformer: T 1.5:1 (1Ø): 32/10.7 T 1.5:1 (3Ø): 10.7/Ø T 2.0:1 (1Ø): 24/8 T 2.0:1 (3Ø): 8/Ø T 2.5:1 (1Ø): 19.2/6.4 T 2.5:1 (3Ø): 6.4/Ø" | 15-1200 | 3Ø | 8 |