Pacific Power Source ECTS2 Series


ECTS2 Series IEC Harmonics & Flicker Test Systems.

The Pacific Power Source EMC Compliance Test Systems use a sophisticated Harmonics and Flicker measurement system and newly designed flicker impedance options to support single and three phase IEC 61000-3 AC harmonics, flicker as well as IEC 61000-4 AC and DC immunity compliance testing of EUTs up to the maximum required current of 75A per phase.

This series consists of several system configurations to accommodate both single and three phase compliance testing at a wide range of power levels. All ECTS2 systems use the same IEC 61000-3 Harmonics and Flicker Emissions and IEC 61000-4 Immunity test software.

Model Comparison - Single Phase Models

ModelRated
Power (VA)
Voltage Max
(L-N) (Vrms)
Rated Current Max (Arms) @ 230VacOutput
Frequency (Hz)
Phase Mode
Output
Cabinet Height (U)
108LMX750Direct: 135/2703.015-5000Option -A
140LMX4000Direct: 135/2701615-500018U
160LMX6000Direct: 135/2701615-500018U

Model Comparison - Three Phase Models

ModelRated
Power (VA)
Voltage Max
(L-N/L-L) (Vrms)
Current Max @ 230Vac (Arms)Output
Frequency (Hz)
Phase Mode
Output
Cabinet Height (U)
ECTS2-360F-n6kVA1Ø: 333
3Ø: 333/576
1Ø: 26
3Ø: 8.7
15-12001, 2, 318
ECTS2-3150F-n15kVA1Ø: 333
3Ø: 333/576
1Ø: 65
3Ø: 21.7
15-12001, 2, 318
ECTS2-3300F-n30kVA1Ø: 333
3Ø: 333/576
1Ø: 130
3Ø: 43.3
15-12001, 2, 318
ECTS2-3450F-n45kVA1Ø: 333
3Ø: 333/576
1Ø: 195
3Ø: 65
15-12001, 2, 328
ECTS2-3600F-n60kVA1Ø: 333
3Ø: 333/576
1Ø: 260
3Ø: 86.9
15-12001, 2, 336
ECTS2-3750F-n75kVA1Ø: 333
3Ø: 333/576
3Ø: 10815-12002, 32 x 36
ECTS2-3900F-n90kVA1Ø: 333
3Ø: 333/576
3Ø: 13015-12002, 32 x 36

Electronic Power Transfer Switch Options

ModelRated Current MaxOutput Form
EPTS-16A-116A
EPTS-16A-316A / Phase
EPTS-32A-132A
EPTS-32A-332A / Phase
EPTS-75A-175A
EPTS-75A-375A / Phase
EPTS-100A-1100A
EPTS-100A-3100A / Phase