PPS AGX Series Regenerative AC & DC Power Source


Regenerative Test Equipment Saves Energy

The AGX Series is a family of fully regenerative, high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 6 kVA to 252 kVA. Using a modern user interface for ease of use, the AGX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power test applications. The AGX Series offers extended voltage and frequency ranges and standard analog and digital I/O functions. The optional Electronic Load function returns energy back to the utility, saving utility and HVAC cost when using the AGX for burn in or other load applications

Don't need the regenerative capabilities? Check out the AFX Series, also from Pacific Power Source.

 

Model Comparison

ModelPhase ModeRated Power* (AC/DC)Voltage RangeMax, AC/DC Current (3 & 2 Phase Mode)Max, AC/DC Current (1 Phase Mode)Form Factor
360AGX-41,2 & 36 kVA, kW
6 kW
0-350 Vac
0-500 Vdc
16.7Arms
8.4Adc
50Arms
25Adc
4U Chassis
390AGX-41,2 & 39 kVA, kW
9 kW
0-350 Vac
0-500 Vdc
25Arms
13.9Adc
75Arms
37.5Adc
4U Chassis
3120AGX-41,2 & 312 kVA, kW
12 kW
0-350 Vac
0-500 Vdc
33.3Arms
16.7Adc
100Arms
50Adc
4U Chassis
3150AGX-41,2 & 315 kVA, kW
15 kW
0-350 Vac
0-500 Vdc
41.7Arms
21Adc
125Arms
62.5Adc
4U Chassis
3180AGX-41,2 & 318 kVA, kW
18 kW
0-350 Vac
0-500 Vdc
41.7Arms
21Adc
125Arms
62.5Adc
4U Chassis
3210AGX-41,2 & 321 kVA, kW
21 kW
0-350 Vac
0-500 Vdc
41.7Arms
21Adc
125Arms
62.5Adc
4U Chassis
3240AGX-42 & 324 kVA, kW
24 kW
0-350 Vac
0-500 Vdc
66.7Arms
33.4Adc
Parallel units - 8U
3300AGX-42 & 330 kVA, kW
30 kW
0-350 Vac
0-500 Vdc
83.3Arms
41.7Adc
Parallel units - 8U
3360AGX-42 & 336 kVA, kW
36 kW
0-350 Vac
0-500 Vdc
83.3Arms
41.7Adc
Parallel units - 8U
3420AGX-42 & 342 kVA, kW
42 kW
0-350 Vac
0-500 Vdc
83.3Arms
41.7Adc
Parallel units - 8U
3630AGX-42 & 363 kVA, kW
63 kW
0-350 Vac
0-500 Vdc
125.0Arms
62.5Adc
Parallel units - 12U
3840AGX-42 & 384 kVA, kW
84 kW
0-350 Vac
0-500 Vdc
166.7Arms
83.3Adc
Parallel units - 16U
31050AGX-42 & 3105 kVA, kW
105 kW
0-350 Vac
0-500 Vdc
208.3Arms
104.2Adc
Parallel units - 20U
31260AGX-42 & 3126 kVA, kW
126 kW
0-350 Vac
0-500 Vdc
250.0Arms
125.0Adc
Parallel units - 24U
31470AGX-42 & 3147 kVA, kW
147 kW
0-350 Vac
0-500 Vdc
291.7Arms
148.8Adc
Parallel units - 28U
3680AGX-42 & 3168 kVA, kW
168 kW
0-350 Vac
0-500 Vdc
333.3Arms
166.7Adc
Parallel units - 32U
* Rated power shown is for Three Phase or Single Phase mode operation. For Split Phase mode, rated power is 2/3.

Single Voltage Range with Constant Power Profile

Traditional AC power sources use two voltage ranges to provide either high voltage or high current. By contrast, the AGX Series uses a unique single voltage range that operates along a constant power curve. This provides more current at low voltages, eliminating the need to switch between voltage ranges and provides a much wider operating range (demonstrated as green in the figure below).

Switching voltage ranges on other AC sources causes the output to be turned off and the EUT to shut down. This makes it difficult to test universal wide input range AC products.

The blue line and green shaded area in the chart shows the additional operating range available compared to a conventional AC power source with a 175V/350V range pair. The same applies to DC mode of operation where a single 500Vdc voltage range is used to provide both high DC current and DC voltage.